Loading...
CC RESOLUTION 511rp. #6t3 RESOLUTION N0. 51 A RESOLUTION OF TEE CITY COUNCIL OF T19 CITY OF EL SEGUNDO, CALIFORNIA, ARMING RESOLUTION NO. 503 OF SAID CITY, BY AMENDING THE "SPECIFI- CATIONS NO. 1940 -A FOR FIRE APPARATUS AND E04UIPMENT, CITY OF EL SEGUNDO, CALIFORNIA." THEREIN REFERRED TO, IN CERTAIN PARTICULARS. The City Council of the City of E1 Segundo, California, does resolve, declare and determine as follows: SECTION 1. That those certain specifications known and designated as "Specifications No. 1940 -A for Fire Apparatus and Equipment, City of E1 Segundo, California. ", adopted by the City Council of the City of E1 Segundo, California, on the 24th day of July, 1940, in and by Resolution No. 503 of said Council, entitled: "A RESOLUTION OF THE CITY COUNCIL OF TIE CITY OF EL SEGUNDO, CALIFORNIA, ADOPTING 'SPECIFICA- TIONS NO. 1940 -A FOR FIRE APPARATUS AND EQUIPMENT, CITY OF EL SEGUNDO, CALIFORNIA. ", shall be and the same are hereby amended in the following par- titulars, to -wit: First: The following sentence is added immediately follow- ing the language now appearing under the heading "STORAGE BATTERIES: "in said specifications, to -wit: "Plug -in sockets for charging batteries shall be installed at a convenient accessible location." Second: The paragraph entitled, "WIDTH: "in said specifications is amended to read as follows: "WIDTH; Over -all width of apparatus shall comply with the provisions of The Vehicle Code of the State of California, 1- 33,dG 1 respecting the width of Motor Vehicles." Third: The following sentence is added immediately following the language now appearing under the heading, .,AXLE RATIO: "in said specifications, to -wit: "Gear shift lever to be equipped with a device for positively holding lever in neutral position during all of time pump is in operation, such device to be adaptable to quick release without use of keys or tools." Fourth: The following sentence is added immediately follow- ing the language now appearing under the heading "WHEELS:" in said specifications, to -wit: "One spare wheel and one spare front tire and tube shall be furnished." Fifth: The paragraph entitled, "LETTERING: "in said speci- fications, is amended to read as follows: "LETTERING: Lettering to be of gold leaf and shaded; size of letters to be in keeping with the apparatus and to be lettered: "Engine Co. No. 3 E1 Segundo Fire Dep't." such lettering to be placed on both sides of apparatus at points to be designated by Fire Chief." Sixth: The paragraph entitled, "ELECTRIC LIGHTS:" in said specifications, is amended to read as follows: 45 �• h One search light, two headlights, two side or dash lights, two rear swivel lights, tail lights, stop light, gauge and underhood lights, and one 'Light from 2- a1•T Mars' or its equal shall be furnished and satisfactorily mounted on the front of ladder canopy." Seventh: The paragraph entitled, "EQUIMNT HOLDERS:" in said specifications is amended to read as follows: "EQUIPMENT HOLDERS: Suitable holders, boxes or other attachments shall be provided for such tools and equipment as the purchaser shall enumerate in the special provisions hereof. Equip- ment holders shall be strong and firmly attached and so designed that equipment will remain in place under all conditions and yet permit of quick adjustment and removal of equipment for use." Eighth: The paragraph entitled, "FIRE PUMP:" in said speei- fications is amended to read as follows: "FIRE PUMP% The fire pump shall be of the centrifugal type, two or more stages series parallel. It shall be of bronze and carefully designed in accordance with the best modern practice. The suitability of materials used, the propor- tions of parts and waterways, clearances, absence of air pockets and flat surfaces under pressure and freedom from vibration and pulsations from water pressure when running at all speeds will be considered in judging the excellence of the design. Pump connections shall be designed to stand a hydrostatic pressure of 600 pounds. Protection against corrosion and provisions for wear and adjustment must be ample and thorough. The pump must be capable of delivering not less than 750 gallons of water per minute against a net pump pressure 3- of 150 pounds per square inch, one half of this quantity at 200 pounds net pressure and one third of the same at 250 pounds net pressure, when drafting water with a lift of 10 feet. Pump must be able to take suction with a lift of 18 feet in 30 seconds with a dry pump. Pumps of larger capacity and corresponding or greater efficiency, which will meet Board of Fire Underwriterb requirements, will be considered. The pump shall be provided with the following connections and equipment: Two side suction inlets of a size ample for the rated capacity, removable strainers to be provided inside each inlet; threads to be suitable for the suction sizes specified for drafting and suitable adapters for the suction sizes to be carried shall also be provided." Ninth: The paragraph entitled, "rMING TEST:* in said specifications is amended to read as follows: "PUMPING TEST: The pumping test shall be made in accordance with the method of the National Board of Fire Underwriters for Acceptance pumping tests. Adequate proof must be furnish- ed that the pumper is of a type that has passed a twelve hour test similar to that prescribed for new types by the National Board of Fire Underwriters. Further, it is specified that no pumper shall be considered that does not meet the requirements of these specifications even though its type has passed the twelve hour test. Addi- tional proof must be furnished that the pumper has been run in before delivery for an adequate period and not less than four hours. 4- "), ) i, ) The pumping test for acceptance shall include the observation of all features concerning pumping operation that have been specified herein. The pumping test shall consist of pumping at the full rated capacity of the pump, as represented by the successful bidder, and in accordance with fire pump test specifications of the Board of Fire Underwriters, against a net pump pressure of 150 pounds for a con- tinuous period of two hours, with a suction lift not to exceed but preferably to amount to ten feet, follow- ed by two one -half hour periods of continuous pumping during one of which at least one half of the full capacity at a net pressure of 200 pounds per square inch shall be delivered, and during the remaining one half hour, one third of the full capacity shall be delivered at 250 pounds net pump pressure. The stops between tests to be only such as are necessary for changing hose and nozzles. During and after tests the pump, motor, transmission and all other parts of the machine shall show no undue heating, excessive strain or vibration and motor shall show no loss of power, over -speed or other defect. The suction hose shall consist of two ten foot lengths and shall not be less than four and one -half inches nor more than six inches in diameter. Suitable adapters shall be provided for attaching suction hose to four inch male hydrant outlets." Tenth: The following sentance is added immediately follow- ing the language now appearing in the second paragraph, under the heading, "BODY:" in said specifications, to -wit: 5- m..�y * f• *C J� D "Cat walks are to be placed between hose bed and truck sides. Ladders are to be placed over hose bed in metal canopy, and roof ladder is to be mounted over the 35' extension ladder." Eleventh: That that certain item which now appears under the heading "EQUIPMENT:" in the following language, "1 - Homelight Generator - 1000 Watt Capacity with 2 flood lights and 1 spotlight. ", shall be and the same is hereby amended so as to read as follows: "l - Homelight or equal Generator - 1000 :Matt Capacity A. C., 5 outlets, filter and breeze shield with 2, 14" diameter flood lights, 500 Watts, and one spot light 250 watts, all trunion mounted." Twelfth: That that certain item which now appears under the heading "EQUIPME[QT7" in the following language, ''1 - 15 pound Carbon Dioxide type extinguisher ", shall be and the same is hereby amended so as to read as follows: "l - 15 pound Carbon Dioxide Valve type extinguisher ". Thirteenth: That the following item is hereby added to the items to be furnished under the heading "EQUIPMENT:" in said specifications, to -wit: "300 feet of 16 gauge, Tirex or equal, rubber covered extension cord." Fourteenth: That the following item mentioned under the heading 6- of "EQUIPMENT:" in said specifications, is hereby eliminated from said specifications, and shall not be furnished, to -wit: "2 - Four inch hard suction hose (10 feet long)" SECTION 2. That said Resolution No. 503 is hereby amended as hereinabove in Section 1 of this resolution set forth. SECTION 3. That the City Clerk shall certify to the passage and adoption of this resolution; shall enter the same is the book of resolutions of said city, and shall make a minute of the passage and adoption thereof in the records of the proceedings of the City Council of said City, in the minutes of the meeting at which the same is passed and adopted. Passed, approved and adopted this 28th day of August, A. D., 1940. ATTEST: City Clerk 3:fiti I Mayor of the City of El Segundo, California. 7- STATE 07 CALIFORNIA, ) ) COUNTY OF LOS ANGELES, ) SS. CITY OF EL SEGUNDO. )) I. Victor D. McCarthy, City Clerk of the City of E1 Segundo, California, do hereby certify that the whole number of members of the City Council of the said City is five; that the foregoing resolution, being Resolution No. 511, was passed and adopted by the said City Council, approved and signed by the Mayor of said City and attested by the City Clerk of said City, all at a regular meeting of the said Council held on the 28th day of August, A. D., 1940, and that the same was so passed and adopted by the following vote: AYES: Councilmen Gerow, `?esser, Love end Pryor Binder; i NOES: Councilmen None ABSENT: Councilmen Selby City Clerk of the City of E1 Segundo, California. NE